Trimble - Transforming the way the world works.

This document provides a list of the Assemblies available in the AutoBid Mechanical database.

To see a drawing of the assembly, select the assembly and touch the F9 key.

HVAC Assemblies

centrifugal chiller

CENTRIFUGAL CHILLER

Condensate Drain at the AHU ½”-2”

exp tank hookup

EXPANSION TANK-Threaded 1”-2”

fan coil unit

FAN COIL UNIT

fin tube down feed

FIN TUBE Radiation (DOWN FEED) ½”-2”

fin tube up feed

FIN TUBE Radiation (UP-FEED/RSR) ½”-2”

hot water boiler

HOT WATER BOILER

humd1thrd

HUMIDIFIER (DUCT MTD) - Threaded 1”-2”

mu water-copper

MAKE-UP WATER LINE (INCL PRV) ½”-2”

shfd.5thru2thrd

SHOT FEEDER - Threaded ½”-2”

Trapeze Angle Iron

Hangers

Trapeze PowerStrut

Hangers

Coil Assemblies

1hwc all sizes

1 - HIGH WATER COIL - (NO TCV Station) ½” - 12”

1hwc2way all sizes

1 - HIGH WATER COIL W/ 2-WAY TCV ½” - 12”

1hwc3w all sizes

1 - HIGH WATER COIL W/ 3-WAY TCV -Welded 2½” - 4”

2hwc all sizes

2 - HIGH WATER COIL - (NO TCV Station) ½” - 12”

2hwc2w all sizes

2 - HIGH WATER COIL W/ 2-WAY TCV ½” - 12”

2hwc3w all sizes

2 - HIGH WATER COIL W3-WAY TCV ½” - 12”

2wtcv all sizes

2-WAY CONTROL VALVE STATION 2 ½” - 12”

3hwc all sizes

3 - HIGH WATER COIL W/ 2-WAY TCV 2 ½” - 12”

3hwc2w all sizes

3 - HIGH WATER COIL W/ 2-WAY TCV 2 ½” - 12”

3hwc3w all sizes

3 - HIGH WATER COIL W/ 3-WAY TCV 2 ½” - 12”

3wtcv all sizes

3-WAY CONTROL VALVE STATION 2 ½” - 12”

rhc2w all sizes

REHEAT COIL (INCL 2-WAY TCV) ½” – 2”

rhc3w all sizes

REHEAT COIL (INCL 3-WAY TCV) ½” - 2”

Heat exchangers

hxhw1thrd

HEAT EXCH – WATER SIDE ½” - 2”

hxhw2.5wld

HEAT EXCH – WATER SIDE 2 ½” – 10”

hxs1.5thrd

HEAT EXCH – STEAM SIDE (NO PRV STA) -Thrd 1 ½” - 2”

hxs1prv1.5thrd

HEAT EXCH – STEAM SIDE w/ (1) PRV -Thrd 1 ½” - 2”

hxs1prv2.5plus

HEAT EXCH – STEAM SIDE w/ (1) PRV -Welded 2 ½” - 14”

hxs2.5+SteamSide

HEAT EXCH – STEAM SIDE (NO PRV STA) -Welded 2 ½” - 14”

hxs2prv2.5plus

HEAT EXCH – STEAM SIDE w/ 1/3 – 2/3 PRV -Weld 2 ½” - 14”

Pumps

Condensate Drain @ PUMP ½” - 2”

espm all sizes

END SUCTION PUMP 2 ½” - 12”

hspm 2.5 plus

HORIZONTAL SPLIT - CASE PUMP 2 ½” - 16”

ilpm all sizes

INLINE PUMP 2 ½” - 16”

vspm2.5plus

VERTICAL SPLIT - CASE PUMP 2 ½” - 16”

Steam Coils

1hsc.5thru2thrd

1 HIGH STEAM COIL - THREADED (NO PRV Station) ½” - 2”

1hsc1prv1.25thrd

1 HIGH STEAM COIL - SINGLE PRV - THRD 1 ¼” - 2”

1hsc1prv2.5plus

1 HIGH STEAM COIL - SINGLE PRV - Welded 2 ½” - 12”

1hsc2.5wld

1 HIGH STEAM COIL - WELDED (NO PRV Station) 2 ½” - 4”

2hsc1prv2.5plus

2 HIGH STEAM COIL w/ SINGLE PRV - Welded 2 ½” - 12”

2hsc2.5plus

2 HIGH STEAM COIL - WELDED (NO PRV Station) 2 ½” - 12’

2hsc2prv2.5plus

2 HIGH STEAM COIL w/ 1/3 - 2/3 PRV -Welded 2 ½” - 8”

3hsc2.5plus

3 HIGH STEAM COIL - WELDED (NO PRV Station) 2 ½” - 10”

3hsc2prv2.5plus

3 HIGH STEAM COIL w/ 1/3 - 2/3 PRV -Welded 2 ½” - 12”

drip w/ check vlv

Steam Trap with check valve

drip w/o check vlv

Steam Trap without check valve

Steam Press Red Sta

1prv.5thru2thrd

SINGLE VALVE STEAM CONTROLLER Station -Threaded ½” - 2”

1prv2.5wld

SINGLE VALVE STEAM CONTROLLER STA -Welded 2 ½” - 4”

2prv2.5wld

1/3 - 2/3 STEAM CONTROL STA. - Welded 2 ½” - 14”

Unit Heaters

cabinet unit htr

CABINET UNIT HEATER (DOWN-FED) ½” - 2”

uh.5thru2

HOT WATER UNIT HEATER ½” - 2”

uhs.5thru2thrd

STEAM UNIT HEATER - Threaded ½” - 2”

Plumbing Assemblies - Battery w/o Carrier (ALL UPPERCASE LETTERS)

1LAV

1 Lavatory

1UR

1 Urinal

1WC

1 Water closet

1WC1LAV

1 Water closet - 1 Lavatory

1WC1LAV1FD

1 Water closet - 1 Lavatory - 1 Floor Drain

1WC1UR1LAV1FD

1 Water closet - 1 Urinal - 1 Lavatory - 1 Floor Drain

1WC2UR2LAV1FD

1 Water closet - 2 Urinals - 2 Lavatories - 1 Floor Drain

2WC2LAV1FD

2 Water closets- 2 Lavatories - 1 Floor Drain

2WC2UR2LAV1FD

2 Water closets- 2 Urinals - 2 Lavatories - 1 Floor Drain

3WC2LAV1FD

3 Water closets- 2 Lavatories - 1 Floor Drain

4LAVS

4 Lavatories

4WC2LAV1FD

4 Water closets- 2 Lavatories - 1 Floor Drain

4WC3LAV1FD

4 Water closets- 3 Lavatories - 1 Floor Drain

BB 2WC2LAV

BB 2 Water closets- 2 Lavatories

BB 2WC2LAV2FD

BB 2 Water closets- 2 Lavatories - 2 Floor Drains

BB 3WC1UR2LAV2FD

BB 3 Water closets- 1 Urinal - 2 Lavatories - 2 Floor Drains

BB 6WC2UR2FD

BB 6 Water closets- 2 Urinals - 2 Floor Drains

BB 6WC2UR4LAV2FD

BB 6 Water closets- 2 Urinals- 4 Lavatories- 2 Floor Drains

This document is for informational purposes only and is not a legally binding agreement or offer. Trimble makes no warranties and assumes no obligations or liabilities hereunder.